Monitoring cell volts by CTX-D during charge |
|
|
|

Here's a tip of monitoring cells voltages with the CTX-D during charging. PLEASE READ CAREFULLY AS INCORRECT OPERATION WILL DAMAGE YOUR EQUIPMENT !
1.Connect your charger to a Power supply. 2.Connect your CTX-D to another separate power supply. 3.Place your battery correctly on the CTX-D 4.Enter into Linear DCH mode. you will see 6 cells voltage. 5.Connect charger to battery then start charge.
You can check each cell's status this way. The CTX-D2 will show you the volts. Weak cells or damaged cells will show you higher voltage during charge. You should always connect the CTX-D to a different power supply. otherwise you will damage the CTX-D or the Charger through a short circuit. The CTX-D does not require a high-amp power supply to run on its own. It consumes about 350mA, so a low amp power supply/AC Adaptor (wired correctly) will work fine. The MM-CTXPM works great for a second power supply!
|